Main Input Voltage | 230 VÂ Â Â |
Product or component type | Uninterruptible power supply (UPS)Â Â Â Â Â Â Â Â |
Other Input Voltage | 220 VÂ Â Â |
Main Output Voltage | 230 VÂ Â Â |
Other Output Voltage | 220 VÂ Â Â |
Rated power in W | 5000 W |
Rated power in VA | 5000 VAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â |
Output connection type | 6 IEC 60320 C13Â Â Â Â Â Â Â Â Â Â Â Â Â Â 4 IEC 60320 C19Â Â Â Â Â Â Â Â Â Â Â Â Â Â |
Number of rack unit | 2UÂ Â Â Â Â Â Â Â Â |
Number of cables | 1Â Â Â Â Â Â Â Â Â Â Â Â |
Battery type | Li-Ion (Lithium-Ion)Â Â Â Â Â Â Â Â |
Provided equipment | 1 CD (software and documentation)       USB cable            Front cover        Earth terminal block       Temperature sensor       Stabilization feet              Rail extension   2P-3P connector              |
Number of battery filled slots | 0Â Â Â Â Â Â Â Â Â Â Â Â |
Number of battery free slots | 0Â Â Â Â Â Â Â Â Â Â Â Â |
Battery recharge time | 1.5 h     |
Number of battery replacement quantity | 1Â Â Â Â Â Â Â Â Â Â Â Â |
Battery voltage | 180 VÂ Â Â |
Battery charger power | 600 W rated      |
Battery life | 5…10 year(s)     |
Extended runtime | 1Â Â Â Â Â Â Â Â Â Â Â Â |
Product web sub-family | High density      |
Number of power module free slots | 0Â Â Â Â Â Â Â Â Â Â Â Â |
Number of power module filled slots | 0Â Â Â Â Â Â Â Â Â Â Â Â |
Redundant | No         |
Colour | Silver grey          |
Height | 86 mm |
Width | 432 mm              |
Depth | 701 mm              |
Net weight | 29.2 kg |
Mounting location | Front    |
Mounting preference | No preference   |
Mounting mode | Rack-mounted  Tower-mounted with kit |
Two post mountable | 0Â Â Â Â Â Â Â Â Â Â Â Â |
USB compatible | No         |
Mounting position | Horizontal          Vertical |
Network frequency | 40...70 Hz auto-sensing |
Number of input connectors | 1 hard wire 3-wire (1P + N + E)Â Â Â |
Input voltage limits | 180...275 V adjustable (half load)Â Â Â Â Â Â Â Â Â Â Â Â Â |
Maximum configurable power in W | 5000 W |
Harmonic distortion | Less than 2 %Â Â Â Â |
Output frequency | 50/60 Hz +/- 3 Hz sync to mains |
Crest factor | 3 : 1Â Â Â Â Â Â |
UPS type | Double conversion online             |
Wave type | Sine wave           |
Bypass type | Internal bypass (automatic and manual) |
Full load runtime | 00:05:00 5000 WÂ Â Â Â Â Â Â Â Â Â Â Â |
Half load runtime | 00:12:00 2500 WÂ Â Â Â Â Â Â Â Â Â Â Â |
Maximum configurable power in VA | 5000 VAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â |
Product certifications | CEÂ Â Â Â Â Â Â Â Â Â UKCAÂ Â Â Â EN/IEC 62040-1 |
Marking | CE Mark              UKCA    |
Ambient air temperature for operation | 0…40 °C               |
Relative humidity | 0…95 % non-condensing              |
Operating altitude | 0...10000 ft        |
Ambient air temperature for storage | -15…45 °C          |
Storage Relative Humidity | 0…95 % non-condensing              |
Storage altitude | 0.00…15240.00 m          |
Acoustic level | 55 dBAÂ |
Heat dissipation | 931 Btu/h           |
IP degree of protection | IP20Â Â Â Â Â Â |
Free slots | 0Â Â Â Â Â Â Â Â Â Â Â Â |
Alarm | Audible and visible alarms : prioritized by severity             |
Emergency power off | Yes         |
Surge energy rate | 1260 JÂ Â |